KTI – SAUTER

KTI - SAUTER hot water concrete heater (HWS)

The KTI - SAUTER hot water systems (HWS) are used in the production of concrete, especially winter concrete. They heat mixing water to 40 - 60 °C under winter conditions without any problems.
KTI - SAUTER hot water concrete heater (HWS)

Plant information

The KTI - SAUTER hot water units are tailored to the requirements of all common concrete mixing plants in terms of system performance and hot water volume. The robust design with a Stainless steel boiler as well as a high performance insulation guarantee 100% performance for years. Hot water system boilers are not classified as pressure vessels, as is the case with commercial water heaters. As a result The annually recurring inspections are omitted - this reduces ongoing operating costs. All hot water systems are available as stand-alone, independent units for installation in buildings or as containerized solutions. They are equipped with LO-NOx burner equipped with different fuels can be operated - biodiesel, biogas are available in addition to the classic fuels. Most often, a hot water system is used in Combination with a hot air unit (OLH) for heating the silos are installed together. However, both systems can always be operated independently, as required.
KTI - SAUTER hot water concrete heater (HWS)

The most important details at a glance

4
sizes
0
Pressure vessel
85
°C max. water temperature
97%
Efficiency with Efficiency Package
KTI - SAUTER hot water concrete heater (HWS)

Your advantages of KTI - SAUTER hot water systems

  1. KTI - SAUTER hot water concrete heater Reduce ongoing maintenance costs*.
  2. KTI - SAUTER hot water systems can be equipped with climate-friendly fuels be operated.
  3. KTI - SAUTER hot water systems always contain the Latest burner technology.
  4. KTI - SAUTER hot water systems are Extremely durable.
  5. KTI - SAUTER hot water systems are Flexible and variable use.
* The hot water system boiler is not classified as a pressure vessel and therefore does not require an annual mandatory inspection.
KTI - SAUTER hot water concrete heater (HWS)

Two installation possibilities offer special advantages

Direct installation In the direct installation, fresh water supplied as required is heated and consumed. As the KTI - SAUTER hot water system heats water without pressure, a water feed pump is installed to feed the hot water directly into the concrete mixing plant or to the truck mixer. A essential advantage of this design is that no additional water-to-water heat exchanger needs to be installed. The Total energy in the water can therefore be used.   Indirect installation Indirect heating of water by means of a heat transfer station provides the AdvantageThe water pressure of the public sewer system is used to supply the mixing plant or truck mixer with the water to be added. An indirect installation consists of a closed heating circuit between the hot water system and a so-called transfer station. Due to the closed heating circuit, there is almost no contamination of the heat exchangers in the installation. This has a positive effect on maintenance costs. The circulating pump installed in this system requires only about 10 % of current of a hot water feed pump as used for direct installation. The only drawback is the loss in the transfer station.   The direct and indirect installation variants can be supplemented by additional heat exchangers for a space heating system or other applications.be expanded.

KTI - Insight

The HWS hot water system is a "must-have" for all those who want to heat up addition water for concrete production in winter. The HWS is very easy to operate and very flexible to use. The stainless steel boiler is on the one hand very durable, as no corrosion can occur, and on the other hand the pressureless water supply saves the annual inspection by the TĂśV. In the long run, both of these factors benefit maintenance and operating costs.
Often the HWS is used together with our air heater OLH as a package. My customers receive two independently running plants. This means that only one unit can be operated in the off-season. If it gets even colder, the other unit can simply be switched on.
Bruno Leemann
Sales Engineer Concrete Heating, KTI-Plersch Kältetechnik GmbH
KTI - SAUTER hot water concrete heater (HWS)

Product details

HWS 300HWS 500HWS 1000HWS 1500
Heating capacity300 kW500 kW920 kW1320 kW
Max. Water temperature85 °C85 °C85 °C85 °C
Water volume (dT = 40°C)6 m³/h9.7 m³/h18.6 m³/h26.7 m³/h
Water volume (dT = 60°C)4 m³/h6.6 m³/h12.4 m³/h17.8 m³/h
Boiler volume2,6 mÂł3,8 mÂł6,2 mÂł9 mÂł
KTI - SAUTER hot water concrete heater (HWS)

Gallery

KTI - Sauter hot water concrete heater in operation at dam project in Patagonia. In winter, up to 1000 kW heating capacity is required to bring the water to the right temperture.

KTI - SAUTER hot water system combined with air heater installed in a common container.

The hot water system can be seen on the left of the picture. The separate control system allows hot water to be produced independently of the hot air system (right).

KTI - SAUTER hot water concrete heater (HWS)

Optimal application in this industry

KTI – SAUTER

We are here for you

Your contact to our experts

How would you like to be contacted?

„*“ zeigt erforderliche Felder an

Your personal contact to our experts

You wish to be contacted by telephone. Please fill in the following form fields so that we can provide you with targeted support. Thank you

Your name*
MM Schrägstrich TT Schrägstrich JJJJ
Consent*

„*“ zeigt erforderliche Felder an

Your personal contact to our experts

You wish to be contacted by e-mail. Please fill in the following form fields so that we can provide you with targeted support. Thank you

Your name*
MM Schrägstrich TT Schrägstrich JJJJ
Consent*

„*“ zeigt erforderliche Felder an

Your personal contact to our experts

You wish to be contacted in a different way, e.g. by video call. Please fill in the following form fields so that we can provide you with targeted support. Thank you

Your name*
MM Schrägstrich TT Schrägstrich JJJJ
Consent*